Bull 57569 Instrucciones de operaciones Pagina 4

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 16
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 3
NOTE TO INSTALLER: Leave these instructions with the consumer for future reference. Your grill must be installed in accordance
with all local building codes.
SPECIFICATIONS FOR BARBECUE STRUCTURE
1. Masonry of your choice can be used for cabinet construction for the built-in gas grill. It must be non- combustible material. Keep
in mind when choosing a location for your grill that it should NOT be located under any overhead combustible construction.
Upper and ground level vents must be provided for combustion air on both sides of built-in cabinet. Vents on BBQ bowl must
remain unobstructed to allow for combustion air.
2. The BBQ Grill requires a wall opening of the following dimensions: See PAGE 5 & 6 for different models
3. Place gas grill assembly into wall opening as shown in illustration on pages 5 and 6. BBQ rests on side and back edges of BBQ
bowl.
4. For Propane Gas LP TANK STORAGE AREA MUST BE ISOLATED FROM GRILL AND VENTED.
5. Do not use any combustible materials for this construction. Minimum horizontal clearance to adjacent combustible surface
from side and back of the grill must be 21 inches.
CONNECTING TO GAS SOURCE
Refer to the following instructions and illustrations for typical gas supply connections. We strongly suggest professional
installation and hook-up of the Gas BBQ.
IMPORTANT: Before connecting grill to gas source, make sure BBQ Grill control knobs are in “OFF” position.
NATURAL GAS CONNECTIONS
Pipe sealing compound or pipe thread tape of the type resistant to the
action of natural gas must be used on all male pipe thread. Apply compound
or tape to at least the first three threads when making the connection.
Remove plastic cap from regulator installed on grill.
Attach stainless steel flex line 3/8” flare-female end to the regulator.
Attach the other end of flex line to shut-off valve thru a nipple.
Attach a shut-off valve to gas supply pipe.
PERFORM GAS LEAK CHECK -SEE PAGE 2
PROPANE GAS CONNECTIONS
The LP gas pressure regulator and hose assembly supplied with this unit
must be used without alteration. If this assembly needs to be replaced, use
only the type 1 specified in the parts list supplied with this unit.
Use an LP tank with a type 1 cylinder valve. Make sure the tank is firmly
secured in an upright position.
Turn the black coupling nut of the hose and regulator assembly in a
clockwise direction. Make sure it is completely threaded onto the cylinder
valve before turning gas supply on.
PERFORM GAS LEAK CHECK — SEE PAGE 2
4
OUTDOORS
NATURAL GAS BBQ INSTALLATION SPECIFICATIONS
NOTE:
Vents must be provided for combustion air on both sides of built-in cabinet.
When choosing a location for your gas grill keep in mind that it should never be located under any overhead
combustible construction.
The sides and back of the grill should not be any closer than 21 inches to combustible construction.
Vista de pagina 3